Lincoln Nautilus Manuals

Lincoln Nautilus: Climate Control System - General Information / Electronic Leak Detection. General Procedures

Inspection

  1. NOTE: Depending on refrigerant used:

    • Use a Rotunda-approved Electronic Leak Detector for R134a refrigerant SAE Certified to J2791.
    • Use a Rotunda-approved Electronic Leak Detector for R-1234yf refrigerant SAE Certified to J2913.

    NOTE: Good ventilation is necessary in the area where electronic A/C leak testing is to be carried out. If the surrounding air is contaminated with refrigerant gas, the leak detector indicates this gas all the time. Odors from other chemicals such as antifreeze, disc brake cleaner or other cleaning solvents can cause the same problem. Using a fan to ventilate the area to be tested before proceeding with the leak detection procedure is helpful in removing small traces of contamination from the air, but the fan should be turned off during actual testing.

    NOTE: If the surrounding air is contaminated with refrigerant gas, the leak detector indicates this gas all the time. Odors from other chemicals such as antifreeze, disc brake cleaner or other cleaning solvents can cause the same problem.

    NOTE: R134a or R-1234yf, if present, is heavier than air, and tends to move down from the source of the leak. It is possible that a leak may not be detected if the leak detector tip is held above the leaking fitting, line or component. Always be sure to thoroughly leak test below, above and around the fitting, line or component for the presence of R134a or R-1234yf.

    Leak check the service ports. Remove caps and blow air over the service ports to remove trapped refrigerant before leak testing ports.
    • For access to the correct Ford approved Refrigerant Leak Detector.
      Refer to: Climate Control Tools and Equipment (412-00 Climate Control System - General Information, General Procedures).
  1. NOTE: The system pressure should be 413-551 kPa (60 - 80 psi) at 24° C (75.2° F) with the engine off and cool. The pressure reading may be higher if the engine is hot.

    Leak test the refrigerant system. Follow the instructions included with the Electronic Leak Detector for handling and operation techniques.

    Condenser Core Leak Check. General Procedures

    Inspection Recover the refrigerant. Refer to: Air Conditioning (A/C) System Recovery, Evacuation and Charging (412-00 Climate Control System - General Information, General Procedures)...

    Evaporator Core Leak Check. General Procedures

    Inspection Recover the refrigerant. Refer to: Air Conditioning (A/C) System Recovery, Evacuation and Charging (412-00 Climate Control System - General Information, General Procedures)...

    Other information:

    Lincoln Nautilus 2018-2024 Service Manual: Spring. Removal and Installation


    Special Tool(s) / General Equipment Spring Compressor Vise Removal NOTICE: Suspension fasteners are critical parts that affect the performance of vital components and systems. Failure of these fasteners may result in major service expense...

    Lincoln Nautilus 2018-2024 Service Manual: Tire Pressure Monitoring System (TPMS) Sensor Activation. General Procedures


    Special Tool(s) / General Equipment 204-D081A (204-D081) Tire Pressure Monitor (TPMS) Activation NOTE: The tire pressure sensors will go into a "sleep mode" when a vehicle is stationary to conserve battery power. The sensors do not transmit information while in sleep mode...

    Categories

    Clearing the Garage Door Opener. Reprogramming the Garage Door Opener. Garage Door Opener Radio Frequencies

    Clearing the Garage Door Opener

    Lincoln Nautilus. Clearing the Garage Door Opener. Reprogramming the Garage Door Opener. Garage Door Opener Radio Frequencies

    Press and hold the outer two function buttons simultaneously for approximately 10 seconds until the indicator light above the buttons flashes rapidly. When the indicator light flashes, release the buttons.

    read more

    Copyright © 2024 www.linautilus.com